2025-07-24 15:54:47 +02:00
|
|
|
/**
|
|
|
|
* Represents a MQTT Water Heater component for Home Assistant MQTT Discovery.
|
|
|
|
*
|
|
|
|
* The `mqtt` water heater platform lets you control your MQTT enabled water heater devices.
|
|
|
|
*
|
|
|
|
* For detailed documentation see:
|
|
|
|
* https://www.home-assistant.io/integrations/water_heater.mqtt/
|
|
|
|
*/
|
|
|
|
export interface WaterHeaterComponent {
|
|
|
|
/**
|
|
|
|
* Must be `water_heater`.
|
|
|
|
* Only allowed and required in [MQTT auto discovery device messages](https://www.home-assistant.io/integrations/mqtt/#device-discovery-payload).
|
|
|
|
*/
|
|
|
|
platform: 'water_heater';
|
|
|
|
|
|
|
|
/**
|
|
|
|
* An ID that uniquely identifies this water heater.
|
|
|
|
* If two water heaters have the same unique ID, Home Assistant will raise an exception.
|
|
|
|
* Required when used with device-based discovery.
|
|
|
|
*/
|
2025-07-24 20:57:05 +02:00
|
|
|
unique_id: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
|
|
*/
|
|
|
|
entity_category?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Picture URL for the entity.
|
|
|
|
*/
|
|
|
|
entity_picture?: string;
|
2025-07-24 15:54:47 +02:00
|
|
|
|
|
|
|
/**
|
|
|
|
* The name of the water heater.
|
2025-07-25 13:32:50 +02:00
|
|
|
*
|
|
|
|
* It is recommended to set the name when entity identifiers (such as `device_class` or `state_class`)
|
|
|
|
* do not accurately represent the purpose of the entity, to avoid showing the default 'MQTT' name.
|
|
|
|
*
|
2025-07-24 15:54:47 +02:00
|
|
|
* Default: "MQTT water heater"
|
|
|
|
*/
|
|
|
|
name?: string | null;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Used instead of `name` for automatic generation of `entity_id`.
|
|
|
|
*/
|
|
|
|
object_id?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Flag which defines if the entity should be enabled when first added.
|
|
|
|
* Default: true
|
|
|
|
*/
|
|
|
|
enabled_by_default?: boolean;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The encoding of the payloads received and published messages.
|
|
|
|
* Set to `""` to disable decoding of incoming payload.
|
|
|
|
* Default: "utf-8"
|
|
|
|
*/
|
|
|
|
encoding?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* [Icon](https://www.home-assistant.io/docs/configuration/customizing-devices/#icon) for the entity.
|
2025-07-25 13:32:50 +02:00
|
|
|
*
|
|
|
|
* The icon must be a Material Design Icons (MDI) string identifier, for example: `mdi:thermometer`, `mdi:battery`, or `mdi:water`.
|
|
|
|
*
|
|
|
|
* It is recommended to set the icon when the default icon or other entity identifiers (such as `device_class` or `state_class`)
|
|
|
|
* do not accurately represent the purpose of the entity. In most cases, relying on the automatic icon selection ensures better consistency
|
|
|
|
* and compatibility with future updates.
|
2025-07-24 15:54:47 +02:00
|
|
|
*/
|
|
|
|
icon?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The payload that represents the available state.
|
|
|
|
* Default: "online"
|
|
|
|
*/
|
|
|
|
payload_available?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The payload that represents the unavailable state.
|
|
|
|
* Default: "offline"
|
|
|
|
*/
|
|
|
|
payload_not_available?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic to publish commands to change the water heater operation mode.
|
|
|
|
*/
|
|
|
|
mode_command_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A template to render the value sent to the `mode_command_topic` with.
|
|
|
|
*/
|
|
|
|
mode_command_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic to subscribe for changes of the water heater operation mode.
|
|
|
|
* If this is not set, the operation mode works in optimistic mode (see below).
|
|
|
|
* A "None" payload resets to an `unknown` state. An empty payload is ignored.
|
|
|
|
*/
|
|
|
|
mode_state_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A template to render the value received on the `mode_state_topic` with.
|
|
|
|
*/
|
|
|
|
mode_state_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A list of supported modes.
|
|
|
|
* Needs to be a subset of the default values.
|
|
|
|
* Default: ['off', 'eco', 'electric', 'gas', 'heat_pump', 'high_demand', 'performance']
|
|
|
|
*/
|
|
|
|
modes?: string[];
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic to publish commands to change the water heater power state.
|
|
|
|
* Sends the payload configured with `payload_on` if the water heater is turned on via the `water_heater.turn_on`,
|
|
|
|
* or the payload configured with `payload_off` if the water heater is turned off via the `water_heater.turn_off` action.
|
|
|
|
* Note that `optimistic` mode is not supported through `water_heater.turn_on` and `water_heater.turn_off` actions.
|
|
|
|
* When called, these actions will send a power command to the device but will not optimistically update the state of the water heater.
|
|
|
|
* The water heater device should report its state back via `mode_state_topic`.
|
|
|
|
*/
|
|
|
|
power_command_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A template to render the value sent to the `power_command_topic` with.
|
|
|
|
* The `value` parameter is the payload set for `payload_on` or `payload_off`.
|
|
|
|
*/
|
|
|
|
power_command_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The payload that represents enabled state.
|
|
|
|
* Default: "ON"
|
|
|
|
*/
|
|
|
|
payload_on?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The payload that represents disabled state.
|
|
|
|
* Default: "OFF"
|
|
|
|
*/
|
|
|
|
payload_off?: string;
|
|
|
|
|
|
|
|
/**
|
2025-07-25 13:32:50 +02:00
|
|
|
* Flag that defines if the water heater works in optimistic mode (not waiting for state update before showing the change in Home Assistant).
|
2025-07-24 15:54:47 +02:00
|
|
|
* Default: "`true` if no state topic defined, else `false`."
|
|
|
|
*/
|
|
|
|
optimistic?: boolean;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic to publish commands to change the target temperature.
|
|
|
|
*/
|
|
|
|
temperature_command_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A template to render the value sent to the `temperature_command_topic` with.
|
|
|
|
*/
|
|
|
|
temperature_command_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic to subscribe for changes in the target temperature.
|
|
|
|
* If this is not set, the target temperature works in optimistic mode (see below).
|
|
|
|
* A `"None"` value received will reset the temperature set point.
|
|
|
|
* Empty values (`'''`) will be ignored.
|
|
|
|
*/
|
|
|
|
temperature_state_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A template to render the value received on the `temperature_state_topic` with.
|
|
|
|
*/
|
|
|
|
temperature_state_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Defines the temperature unit of the device, `C` or `F`.
|
|
|
|
* If this is not set, the temperature unit is set to the system temperature unit.
|
|
|
|
*/
|
|
|
|
temperature_unit?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The desired precision for this device.
|
|
|
|
* Can be used to match your actual water heater's precision.
|
|
|
|
* Supported values are `0.1`, `0.5` and `1.0`.
|
|
|
|
* Default: 0.1 for Celsius and 1.0 for Fahrenheit.
|
|
|
|
*/
|
|
|
|
precision?: number;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Set the initial target temperature.
|
|
|
|
* The default value depends on the temperature unit, and will be 43.3°C or 110°F.
|
|
|
|
*/
|
|
|
|
initial?: number;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Maximum set point available.
|
|
|
|
* The default value depends on the temperature unit, and will be 60°C or 140°F.
|
|
|
|
*/
|
|
|
|
max_temp?: number;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Minimum set point available.
|
|
|
|
* The default value depends on the temperature unit, and will be 43.3°C or 110°F.
|
|
|
|
*/
|
|
|
|
min_temp?: number;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* A template with which the value received on `current_temperature_topic` will be rendered.
|
|
|
|
*/
|
|
|
|
current_temperature_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic on which to listen for the current temperature.
|
|
|
|
* A `"None"` value received will reset the current temperature.
|
|
|
|
* Empty values (`'''`) will be ignored.
|
|
|
|
*/
|
|
|
|
current_temperature_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Defines a [template](https://www.home-assistant.io/docs/configuration/templating/#using-value-templates-with-mqtt)
|
|
|
|
* to extract the JSON dictionary from messages received on the `json_attributes_topic`.
|
|
|
|
* Usage example can be found in [MQTT sensor](https://www.home-assistant.io/integrations/sensor.mqtt/#json-attributes-template-configuration) documentation.
|
|
|
|
*/
|
|
|
|
json_attributes_template?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The MQTT topic subscribed to receive a JSON dictionary payload and then set as sensor attributes.
|
|
|
|
* Usage example can be found in [MQTT sensor](https://www.home-assistant.io/integrations/sensor.mqtt/#json-attributes-topic-configuration) documentation.
|
|
|
|
*/
|
|
|
|
json_attributes_topic?: string;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* The maximum QoS level to be used when receiving and publishing messages.
|
|
|
|
* Default: 0
|
|
|
|
*/
|
|
|
|
qos?: number;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Defines if published messages should have the retain flag set.
|
|
|
|
* Default: false
|
|
|
|
*/
|
|
|
|
retain?: boolean;
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Default template to render the payloads on *all* `*_state_topic`s with.
|
|
|
|
*/
|
|
|
|
value_template?: string;
|
|
|
|
}
|